 Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
BARRACUDATM SERIES
Features
Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) High and flat efficiency profile >95.0% at 12Vdc, 30% to 100% rated output Wide input voltage range: 36-75Vdc Delivers up to 33Adc output current Remote sense and output voltage trim Fully regulated output voltage Output voltage adjust: 8.1Vdc to 13.2Vdc Low output ripple and noise Industry standard, DOSA compliant, Quarter brick: 57.9 mm x 36.8 mm x 10.6 mm (2.28 in x 1.45 in x 0.42 in) Constant switching frequency Positive remote On/Off logic Output over current/voltage protection Digital interface with PMBusTM Rev.1.1 compliance Over temperature protection Wide operating temperature range (-40C to 85C) UL* 60950-1 Recognized, CSA C22.2 No. 60950-103 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed CE mark 73/23/EEC and 96/68/EEC directives Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation rating per EN60950-1 2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE standards ISO** 9001 and ISO14001 certified manufacturing facilities
RoHS Compliant
Applications
Distributed power architectures Intermediate bus voltage applications Servers and storage applications Networking equipment including Power over Ethernet (PoE) Fan assemblies other systems requiring a tightly regulated output voltage
Options
Negative Remote On/Off logic Active load sharing (Parallel Operation) Baseplate option (-H) Auto restart after fault shutdown



Description
The QBDW033A0B series of dc-dc converters are a new generation of DC/DC power modules designed to support 9.6 -12Vdc intermediate bus applications where multiple low voltages are subsequently generated using point of load (POL) converters, as well as other application requiring a tightly regulated output voltage. The QBDW033A0B series operate from an input voltage range of 36 to 75Vdc and provide up to 33A output current at output voltages from 8.1Vdc to 12Vdc in a DOSA standard quarter brick. The converter incorporates digital control, synchronous rectification technology, a fully regulated control topology, and innovative packaging techniques to achieve efficiency approaching 97% peak at 12Vdc output. This leads to lower power dissipations such that for many applications a heat sink is not required. Standard features include output voltage trim, remote sense, on/off control, output overcurrent and over voltage protection, over temperature protection, input under and over voltage lockout, power good signal and PMBus interface. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. Builtin filtering for both input and output minimizes the need for external filtering.
* UL is a registered trademark of Underwriters Laboratories, Inc.

CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
Document No: ADS10-006 ver 0.3 PDF Name: QBDW033A0B_ADS.pdf
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter Input Voltage* Continuous Operating transient 100mS Operating Input transient slew rate, 50VIN to 75VIN (Output may exceed regulation limits, no protective shutdowns shall activate, CO=220F to CO, max) Non- operating continuous Operating Ambient Temperature (See Thermal Considerations section) Storage Temperature All Tstg -55 125 C Vdc I/O Isolation Voltage (100% factory Hi-Pot tested) All 2250 * Input over voltage protection will shutdown the output voltage when the input voltage exceeds threshold level. All VIN TA 80 -40 VIN -0.3 75 100 12.5 100 85 Vdc Vdc V/s Vdc C Device Symbol Min Max Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter Operating Input Voltage Maximum Input Current (VIN=0V to 75V, IO=IO, max) Input No Load Current (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current (VIN = VIN, nom, module disabled) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN= 48V, IO= IOmax ; see Figure 10) Input Ripple Rejection (120Hz) All Device Symbol VIN IIN,max IIN,No load IIN,stand-by It
2
Min 36 -
Typ 48 50
Max 75 12
Unit Vdc Adc mA
All All
10 1
mA As
2
All
-
24
-
mAp-p
All
-
50
-
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of TBD A (see Safety Considerations section). Based on the information provided in this Data Sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's Data Sheet for further information.
LINEAGE POWER
2
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Electrical Specifications (continued)
Parameter Output Voltage Set-point (VIN=VIN,nom, IO=15A, TA =25C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (TA = -40C to +85C) Output Voltage Adjustment Range (via Trim resistor or PMBus) Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Output Capacitance Output Current Output Current Limit Inception (Adjustable via PMBus) Efficiency (VIN=VIN, nom, VO= VO,set, TA=25C) IO= 50% IO, max IO= 100% IO, max Switching Frequency Dynamic Load Response (dIo/dt=1A/10s; Vin=Vin,nom; TA=25C; Tested with a 10 F aluminum and a 1.0 F tantalum capacitor across the load.) Load Change from Io= 50% to 75% of Io,max: Peak Deviation Settling Time (Vo<10% peak deviation) Load Change from Io= 75% to 50% of Io,max: Peak Deviation Settling Time (Vo<10% peak deviation) All Vpk ts Vpk ts __ __ __ 300 700 __ __ mVpk s mVpk s All All All All All All CO, max Io IO, lim fsw 220 0 40 96 95 TBD 70 200 10,000 33 mVrms mVpk-pk F Adc Adc % % kHz All All All All 8.1 0.2 0.2 1.0 13.2 % VO, set % VO, set % VO, set Vdc Device All Symbol VO, set Min 11.84 Typ 12 Max 12.12 Unit Vdc
VO
-3.0
+3.0
% VO, set
300 700
Isolation Specifications
Parameter Isolation Capacitance Isolation Resistance Symbol Ciso Riso Min 10 Typ 1000 Max Unit pF M
General Specifications
Parameter Calculated Reliability Based upon Telcordia SR-332 Issue 2: Method I, Case 1, (IO=80%IO, max, TA=40C, Airflow = 200 lfm), 90% confidence Weight - Open Frame Weight - with Baseplate option MTBF FIT Device All All Min Typ TBD TBD TBD TBD Max Unit Hours 10 /Hours g (oz.) g (oz.)
9
LINEAGE POWER
3
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information.
Parameter Remote On/Off Signal Interface (VIN=VIN, min to VIN, max , Signal referenced to VINterminal) Negative Logic: device code suffix "1" Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low Specification On/Off Thresholds: Remote On/Off Current - Logic Low Logic Low Voltage Logic High Voltage - (Typ = Open Collector) Logic High maximum allowable leakage current (Von/off = 2.0V) Maximum voltage allowed on On/Off pin Turn-On Delay and Rise Times (IO=IO, max) (Adjustable via PMBus) Tdelay = Time until VO = 10% of VO,set from either application of Vin with Remote On/Off set to On or operation of Remote On/Off from Off to On with Vin already applied for at least one second. Trise = Time for VO to rise from 10% of VO,set to 90% of VO,set. (Adjustable via PMBus) Output Overvoltage Protection (Adjustable via PMBus) Overtemperature Protection (Adjustable via PMBus) (See Feature Descriptions) (Default) Input Undervoltage Lockout (Adjustable via PMBus) Turn-on Threshold (Default) Turn-off Threshold (Default) Input Overvoltage Lockout (Adjustable via PMBus) Turn-off Threshold (Default) Turn-on Threshold (Default) 78 81 79 82 Vdc Vdc 31 34.5 31.5 36 Vdc Vdc All All Tref All All Tdelay,
Enable with Vin
Device
Symbol
Min
Typ
Max
Unit
All All All All All
Ion/off Von/off Von/off Ion/off Von/off
5 -0.3 2.0
10
15 0.8 3.5 4.0 13.5
A Vdc Vdc A Vdc
13
TBD TBD TBD TBD
17
ms ms ms Vdc C
Tdelay,
Enable with on/off
Trise
LINEAGE POWER
4
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Characteristic Curves
The following figures provide typical characteristics for the QBDW033A0B (12V, 33A) at 25C. The figures are identical for either positive or negative Remote On/Off logic.
VON/OFF (V) (2V/div) VO (V) (5V/div)
INPUT CURRENT, Ii (A)
INPUT VOLTAGE, VO (V)
OUTPUT VOLTAGE
On/Off VOLTAGE
TIME, t (10 ms/div)
Figure 1. Typical Input Characteristic at Room Temperature.
Figure 4. Typical Start-Up Using Remote On/Off with Vin applied, negative logic version shown.
VO (V) (200mV/div) IO (A) (10A/div)
OUTPUT CURRENT, IO (A)
OUTPUT CURRENT OUTPUT VOLTAGE
EFFCIENCY, (%)
TIME, t (500 s/div)
Figure 2. Typical Converter Efficiency Vs. Output current at Room Temperature.
Figure 5. Typical Transient Response to Step change in Load from 25% to 50% to 25% of Full Load at Room Temperature and 48 Vdc Input.
OUTPUT CURRENT OUTPUT VOLTAGE VO (V) (200mV/div) IO (A) (10A/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VO (V) (5V/div)
VIN(V) (20V/div)
TIME, t (20 ms/div)
TIME, t (500 s/div)
Figure 3. Typical Start-Up Using Vin with Remote On/Off enabled, negative logic version shown.
Figure 6. Typical Transient Response to Step Change in Load from 50% to 75% to 50% of Full Load at Room Temperature and 48 Vdc Input.
LINEAGE POWER
5
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Characteristic Curves (continued)
OUTPUT VOLTAGE, VO (V)
36 Vin
48 Vin
VO (V) (50mV/div)
75 Vin
INPUT VOLTAGE, Vin (V)
TIME, t (1s/div)
Figure 7. Typical Output Voltage regulation vs. Input Voltage at Room Temperature.
Figure 9. Typical Output Ripple and Noise at Room Temperature and Io = Io,max.
OUTPUT VOLTAGE, VO (V)
OUTPUT CURRENT, IO (A)
Figure 8. Typical Output Voltage Regulation vs. Output Current at Room Temperature. .
LINEAGE POWER
6
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Test Configurations
Design Considerations
Input Source Impedance
The power module should be connected to a low ac-impedance source. A highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 10, a 330F electrolytic capacitor, Cin, (ESR<0.7 at 100kHz), mounted close to the power module helps ensure the stability of the unit. If the module is subjected to rapid on/off cycles, a 330F input capacitor is required. Consult the factory for further application guidelines.
Note: Measure input reflected-ripple current with a simulated source inductance (LTEST) of 12 H. Capacitor CS offsets possible battery impedance. Measure current as shown above.
Safety Considerations
For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950-1, CSA C22.2 No. 60950-1, and VDE EN60950-1. If the input source is non-SELV (ELV or a hazardous voltage greater than 60 Vdc and less than or equal to 75Vdc), for the module's output to be considered as meeting the requirements for safety extra-low voltage (SELV), all of the following must be true: The input source is to be provided with reinforced insulation from any other hazardous voltages, including the ac mains. One VIN pin and one VOUT pin are to be grounded, or both the input and output pins are to be kept floating. The input pins of the module are not operator accessible. Another SELV reliability test is conducted on the whole system (combination of supply source and subject module), as required by the safety agencies, to verify that under a single fault, hazardous voltages do not appear at the module's output.
Figure 10. Input Reflected Ripple Current Test Setup.
Note: Use a 1.0 F ceramic capacitor and a 10 F aluminum or tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module.
Figure 11. Output Ripple and Noise Test Setup.
CONT ACT AND DISTRIBUTION LOSSES VI(+) II SUPPL Y VI(-) CONT ACT RESIST ANCE VO2 VO1 IO LOAD
Note: Do not ground either of the input pins of the module without grounding one of the output pins. This may allow a non-SELV voltage to appear between the output pins and ground. The power module has safety extra-low voltage (SELV) outputs when all inputs are SELV. The input to these units is to be provided with a maximum TBD A fast-acting (or time-delay) fuse in the unearthed lead.
Note: All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance.
Figure 12. Output Voltage and Efficiency Test Setup.
LINEAGE POWER
7
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Feature Descriptions
OverCurrent Protection
To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry and can endure current limiting continuously. If the OverCurrent (IOUT_OC) condition causes the output voltage to fall below tbdV , the module will shut down and remain latched off. The overcurrent latch is reset by either cycling the input power or by toggling the on/off pin for one second. If the output overload condition still exists when the module restarts, it will shut down again. This operation will continue indefinitely until the overcurrent condition is corrected. A factory configured auto-restart option is also available. An auto-restart feature continually attempts to restore the operation until fault condition is cleared. The IOUT_OC _WARNing and FAULT threshold levels, and IOUT_OC_FAULT_RESPONSE can be reconfigured via the PMBus interface.
Remote On/Off [CONTROL](o)
The module contains an configurable on/off control circuit reference to the VO(-) terminal. Two factory configured remote on/off logic options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high, and on during a logic low. The logic of the ON/OFF(o) pin shall match the logic of the ON/OFF(i) pin. Negative logic, device code suffix "1," is the factorypreferred configuration. The On/Off(o) circuit is powered from an internal bias supply, derived from the output bias voltage. To turn the power module on and off, the user must supply a switch to control the voltage between the On/Off (o) terminal and the VO(-) terminal (Von/off(o)). The switch can be an open collector or equivalent (see Figure 13). A logic low is Von/off(o) = -0.3V to 0.8V. The typical Ion/off(o) during a logic low is TBDA. The switch should maintain a logic-low voltage while sinking TBDA. During a logic high, the maximum Von/off(o) generated by the power module is TBDV. The maximum allowable leakage current of the switch at Von/off(o) = 2.0V is TBDA. If using an external voltage source, the maximum voltage Von/off on the pin is TBDV with respect to the Vi(-) terminal. If not using the remote on/off feature, perform one of the following to turn the unit on: For negative logic, short ON/OFF(o) pin to Vi(-). For positive logic: leave ON/OFF(o) pin open. When both On/Off(i) and On/Off(o) are present, the module shall operate if either is asserted. Using Mfgr_Specif commands, it shall be possible to reconfigure the On/Off logic between positive and negative via PMBus, and it shall also be possible to reconfigure the combination of On/Off(i) and On/Off(o) from OR to AND for module operation.
Remote On/Off [CONTROL](i)
The module contains a standard on/off control circuit reference to the VIN(-) terminal. Two factory configured remote on/off logic options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF(i) pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high, and on during a logic low. Negative logic, device code suffix "1," is the factory-preferred configuration. The On/Off(i) circuit is powered from an internal bias supply, derived from the input voltage terminals. To turn the power module on and off, the user must supply a switch to control the voltage between the On/Off(i) terminal and the VIN(-) terminal (Von/off(i)). The switch can be an open collector or equivalent (see Figure 13). A logic low is Von/off(i) = -0.3V to 0.8V. The typical Ion/off(i) during a logic low is TBDA. The switch should maintain a logic-low voltage while sinking TBDA. During a logic high, the maximum Von/off(i) generated by the power module is TBDV. The maximum allowable leakage current of the switch at Von/off(i)= 2.0V is TBDA. If using an external voltage source, the maximum voltage Von/off(i) on the pin is TBDV with respect to the VIN(-) terminal. If not using the remote on/off feature, perform one of the following to turn the unit on: For negative logic, short ON/OFF(i) pin to VIN(-). For positive logic: leave ON/OFF(i) pin open.
Output Overvoltage Protection
The output overvoltage protection consists of a control circuit, independent of the primary regulation loop, that monitors the voltage on the output terminals and clamps the voltage when it exceeds the overvoltage set point. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage.
Overtemperature Protection
These modules feature an overtemperature protection circuit to safeguard against thermal damage. The circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second.
Input Under/Over voltage Lockout
At input voltages above or below the input under/over voltage lockout limits, module operation is disabled. The module will begin to operate when the input voltage level changes to within the under and overvoltage lockout limits. 8
Figure 13. Remote On/Off Implementation. LINEAGE POWER
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Trim, Output Voltage Programming, TM
Trimming allows the output voltage set point to be increased or decreased; this is accomplished by connecting an external resistor between the TRIM pin and either the VO(+) pin or the VO(-) pin.
V O(+) Rtrim-up LOAD Rtrim-down V O(-)
Feature Descriptions (continued)
Remote Sense
Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections (See Figure 11). The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table: [VO(+) - VO(-)] - [SENSE(+) - SENSE(-)] 0.5 V Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (Maximum rated power = Vo,set x Io,max).
SENSE(+) SENSE(-) VI(+) SUPPL Y II VI(-) VO(+) VO(-) CONT ACT AND DISTRIBUTION LOSSE
T/C1 QBDW033A0B
Figure 12. Circuit Configuration to Trim Output Voltage. Connecting an external resistor (Rtrim-down) between the T/C1 pin and the Vo(-) (or Sense(-)) pin decreases the output voltage set point. To maintain set point accuracy, the trim resistor tolerance should be 1.0%. The following equation determines the required external resistor value to obtain a percentage output voltage change of %
511 Rtrim down 10 . 22 %
IO
LOAD
CONT ACT RESIST ANCE
Where % Vo , set V desired V o , set
100
Figure 11. Circuit Configuration for remote sense .
For example, to trim-down the output voltage of the module by 20% to 9.6V, Rtrim-down is calculated as follows: % 20
Configurable Control Pins
The QBDW033A0B contains two configurable control pins, T/C1 and C2, referenced to the module secondary SIGGND. See Mechanical Views for pin locations. The following table list the available factory configurations for the functions assigned to these pins. Additional configurations can accomplished via the PMBus interface. Following the tables, there is a feature description for each function.
511 10.22 Rtrim down 20
Rtrim down 15 .3k
Connecting an external resistor (Rtrim-up) between the T/C1 pin and the VO(+) (or Sense (+)) pin increases the output voltage set point. The following equations determine the required external resistor value to obtain a percentage output voltage change of %:
5 .11 V o , set (100 %) 511 Rtrim up 10 .22 1 .225 % %
Pin Designation/Function
T/C1 Trim TM Load Share CS C2 Power Good PG Power Good PG
Factory Configuration
Modules without -P Modules with -P
Where
V V o , set % desired V o , set
100
C2 Pin Designation/Function Configurable via PMBus Power Good PG On/Off(o)
For example, to trim-up the output voltage of the module by 5% to 12.6V, Rtrim-up is calculated is as follows: % 5
5 .11 12 .0 (100 5 ) 511 R trim up 10 .22 1 .225 5 5
Rtrim up 102 .2
LINEAGE POWER 9
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Power Good, PG
The QBDW033A0B modules provide a Power Good (PG) signal that is implemented with an open-drain output to indicate that the output voltage is within the regulation limits of the power module. The PG signal will be de-asserted to a low state if any condition such as overtemperature, overcurrent or loss of regulation occurs that would result in the output voltage going TBD% outside the setpoint value. The PG terminal should be connected through a pullup resistor (suggested value TBDK) to a source of TBDVdc or less.
Feature Descriptions (continued)
The voltage between the Vo(+) and Vo(-) terminals must not exceed the minimum output overvoltage protection value shown in the Feature Specifications table. This limit includes any increase in voltage due to remote-sense compensation and output voltage set-point adjustment trim. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power (Maximum rated power = VO,set x IO,max).
Thermal Considerations
The power modules operate in a variety of thermal environments and sufficient cooling should be provided to help ensure reliable operation. Thermal considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. Heat-dissipating components are mounted on the top side of the module. Heat is removed by conduction, convection and radiation to the surrounding environment. Proper cooling can be verified by measuring the thermal reference temperature (THx). Peak temperature (THx) occurs at the position indicated in Figure 14 and 15. For reliable operation this temperature should not exceed the listed temperature threshold.
Active Load Sharing, CS
For additional power requirements, the QBDW033A0B power module can be configured for parallel operation with active load sharing. Good layout techniques should be observed for noise immunity when using multiple units in parallel. To implement active load sharing, the following requirements should be followed:
The Vout(+) and Vout(-) planes of all parallel modules must be connected together with output traces from each module as short as possible to common power planes. The SENSE(+) and SENSE(-) connections to each module should come from a single point in each power plane. The current share (CS) pins of all units in parallel must be connected together. The path of these connections should be as direct as possible. SIGGND is the return for the CS signal for each module; therefore, all modules in parallel must use the same SIGGND. These modules contain circuitry to block reverse current flow upon start-up, when output voltage is present from other parallel modules, eliminating the requirement for external output ORing devices. However, output ORing devices should be used, if fault tolerance is desired in parallel applications. When not using the parallel feature, leave the CS open.
. Figure 14. Location of the thermal reference temperature TH.
Figure 15. Location of the thermal reference temperature TH3 for Baseplate module. LINEAGE POWER 10
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Given: Vin= 48V, IO = 22A, TA = 70 C Determine required airflow (V) (Use Figure 16): V = tbd or greater.
Feature Descriptions (continued)
The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum THx temperature of the power modules is 110 C - 125 C, you can limit this temperature to a lower value for extremely high reliability. Please refer to the Application Note "Thermal Characterization Process For Open-Frame Board-Mounted Power Modules" for a detailed discussion of thermal aspects including maximum device temperatures.
Heat Transfer via Convection
Increased airflow over the module enhances the heat transfer via convection. The thermal derating of figure 16 shows the maximum output current that can be delivered by each module in the indicated orientation without exceeding the maximum THx temperature versus local ambient temperature (TA) for air flows of, Natural Convection, 1 m/s (200 ft./min), 2 m/s (400 ft./min). The use of Figures 16 is shown in the following example: Example What is the minimum airflow necessary for a QBDW033A0B operating at VI = 48 V, an output current of 22A, and a maximum ambient temperature of 70 C in transverse orientation. Solution:
LOCAL AMBIENT TEMPERATURE, TA (C) Figure 16. Output Current Derating for the Open Frame QBDW033A0B in the Transverse Orientation; Airflow Direction from Vin(+) to Vin(-); Vin = 48V.
OUTPUT CURRENT, IO (A)
LINEAGE POWER
11
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
communicate with system controllers. Detailed timing and electrical characteristics of the PMBus can be found in the PMB Power Management Protocol Specification, Part 1, revision 1.1, available at http://pmbus.org. The QBDW033A0B supports both the 100kHz and 400kHz bus timing requirements. The QBDW033A0B is permitted to stretch the clock, as long as it does not exceed the maximum clock LO period of 35ms. All communication over the QBDW033A0B device PMBus interface is required to support the Packet Error Checking (PEC) scheme. The PMBus master must generate the correct PEC byte for all transactions and check the PEC byte returned by the QBDW033A0B. The QBDW033A0B supports a subset of the commands in the PMBus 1.1 specification. Most all of the controller parameters can be programmed using the PMBus and stored as defaults for later use. All commands that require data input or output use the linear format. The exponent of the data words is fixed at a reasonable value for the command and altering the exponent is not supported. Direct format data input or output is not supported by the QBDW033A0B. The supported commands are described in greater detail below. The QBDW033A0B also supports the SMBALERT response protocol. The SMBALERT response protocol is a mechanism by which a slave (the QBDW033A0B) can alert the bus master that it wants to talk. The master processes this event and simultaneously addresses all slaves on the bus (that support the protocol) through the alert response address. Only the slave(s) that caused the alert acknowledges this request. The host performs a modified receive byte operation to get the slave's address. At this point, the master can use the PMBus status commands to query the slave that caused the alert. For more information on the SMBus alert response protocol, see the System Management Bus (SMBus) specification. The QBDW033A0B contains non-volatile memory that is used to store configuration settings and scale factors. The settings programmed into the device are not automatically saved into this non-volatile memory though. The STORE_DEFAULT_ALL command must be used to commit the current settings to non-volatile memory as device defaults. The settings that are capable of being stored in non-volatile memory are noted in their detailed descriptions.
Layout Considerations
The QBDW033 power module series are low profile in order to be used in fine pitch system card architectures. As such, component clearance between the bottom of the power module and the mounting board is limited. Avoid placing copper areas on the outer layer directly underneath the power module. Also avoid placing via interconnects underneath the power module. For additional layout guide-lines, refer to FLTR100V10 Data Sheet.
Through-Hole Lead-Free Soldering Information
The RoHS-compliant, Z version, through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. The non-Z version products use lead-tin (Pb/Sn) solder and RoHS-compliant components. Both version modules are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant, pure tin finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant throughhole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details.
Post Solder Cleaning and Drying Considerations
Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS).
PMBus
The QBDW033A0B series is equipped with a digital PMBus interface to allow the module to be configured, and
LINEAGE POWER
12
Advanced Data Sheet February 10, 2011
Supported PMBus Commands Memory PMBus Management
Cmd Code 0 1 1 7 7 F 3 1 2 9 E 0 h h h h h h Command Name CLEAR_FAULTS STO RE_DEFAULT_ALL RESTO RE_DEFAULT_ALL STATUS_W O RD STATUS_CML MFR_MO DULE_DATE_LO C_SN T ransaction T ype Send Byte Send Byte Send Byte Read W ord Read Byte Read W ord
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Numbe r of Data Byte s 0 0 0 2 1 2
Data De scription
Acce ss
M in
M ax
De fault Re solution
Ste ps
Units
Output Voltage PMBus Management
Cmd Code 01 h 02 h 21 h 23 h 25 h 26 h 28 h 40 h 41 h 60 h 61 h 7Ah 8Bh D0 h D1 h D4 h E1 h T ransaction T ype OPERATIO N R/W Byte ON_OFF_CONFIG R/W Byte VO UT_COMMAND R/W W ord VO UT_CAL_O FFSET R/W W ord VO UT_MARGIN_HIGH R/W W ord VO UT_MARGIN_LOW R/W W ord VO UT_DROO P R/W W ord VO UT_O V_FAULT_LIMIT R/W W ord VO UT_O V_FAULT_RESPO NSE R/W Byte TO N_DELAY R/W W ord TO N_RISE R/W W ord STATUS_VO UT Read Byte READ_VO UT Read W ord MFR_VO UT_READ_CAL_GAIN R/W W ord MFR_VO UT_READ_CAL_O FFSET R/W W ord MFR_LO OP_COMP_BREAKS R/W W ord MFR_MULTI_O N_OFF_PIN_CONFI R/W W ord Command Name Numbe r of Data 1 1 2 2 2 2 2 2 1 2 2 1 2 2 2 2 2 Data De scription Acce ss CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W FACTO RY R/W O NLY CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W CUSTOMER R/W M in M ax De fault Re solution Ste ps Units
Linear Linear Linear Linear Linear Linear Linear Linear
V V V V m V/A (m ?) V mS mS
Input Voltage PMBus Management
C md C ode 35 h 36 h 55 h 56 h 7Ch 88 h D2 h D3 h C ommand N ame VIN_O N VIN_O FF VIN_O V_FAULT_LIMIT VIN_O V_FAULT_R ESPO NSE STATUS_INPUT R EAD_VIN MFR _VIN_R EAD _C AL_GAIN MFR _VIN_R EAD _C AL_O FFSET T ransaction T ype R /W W ord R /W W ord R /W W ord R/W Byte Read Byte R ead W ord R /W W ord R /W W ord N umbe r of Data 2 2 2 1 1 2 2 2 D ata De scription Linear Linear Linear Acce ss M in M ax D e fault R e solution Ste ps U nits V V V 10.5.1. R es pons e To Voltage
Output Current PMBus Management
C md C ode 46 h 47 h 4Ah 7Bh 8Ch C ommand N ame IO UT_O C _FAULT_LIMIT IO UT_O C _FAULT_R ESPO NSE IO UT_O C _W AR N_LIMIT STATUS_IO UT R EAD_IO UT T ransaction T ype R /W W ord R/W Byte R /W W ord Read Byte R ead W ord N umbe r of Data 2 1 2 1 2 D ata De scription Linear Linear Acce ss M in M ax D e fault R e solution Ste ps U nits 10.5.1. R es pons e To Voltage
Temperature Protection PMBus Management
C md C ode 4F h 50 h 51 h 7Dh 8Dh C ommand N ame O T_FAULT_LIMIT O T_FAULT_RESPO NSE O T_W AR N_LIMIT STATUS_TEMPER ATUR E_1 R EAD_TEMPER ATURE_1 T ransaction T ype R /W W ord R/W Byte R /W W ord Read Byte R ead W ord N umbe r of Data 2 1 2 1 2 D ata De scription Linear Linear Acce ss M in M ax D e fault R e solution Ste ps U nits C 10.5.1. R es pons e To Voltage C
Power Good PMBus Management
C md C ode 5Eh 5F h E0 h E2 h T ransaction T ype PO W ER _GO O D _O N R /W W ord PO W ER _GO O D _O FF R /W W ord MFR_MULTI_PIN_CO NFIG R /W Byte MFR_PO W ER_GO O D_PO LAR ITY R /W Byte Command N ame N umbe r of D ata 2 2 1 1 Data De scription Acce ss M in M ax De fault Re solution Ste ps Units
LINEAGE POWER
13
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Mechanical Outline for QBDW033A0B Through-hole Module
Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] *Top side label includes Lineage Power name, product designation, and data code. ** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options.
TOP VIEW*
SIDE VIEW
BOTTOM VIEW Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PinName VIN(+) ON/OFF VIN() VOUT() SENSE() TRIM/C1 SENSE(+) VOUT(+) C2 SIG_GND DATA SMBALERT CLK ADDR1 ADDR0
LINEAGE POWER
14
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Mechanical Outline for QBDW033A0B-H (Baseplate version) Module
Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] *Side label includes product designation, and data code. ** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options. ***Bottom label includes Lineage Power name, product designation, and data code
TOP VIEW
SIDE VIEW*
BOTTOM VIEW*** Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PinName VIN(+) ON/OFF VIN() VOUT() SENSE() TRIM/C1 SENSE(+) VOUT(+) C2 SIG_GND DATA SMBALERT CLK ADDR1 ADDR0
LINEAGE POWER
15
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Recommended Pad Layouts
Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.[ (unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.]
Through-Hole Modules
Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
PinName VIN(+) ON/OFF VIN() VOUT() SENSE() TRIM/C1 SENSE(+) VOUT(+) C2 SIG_GND DATA SMBALERT CLK ADDR1 ADDR0
LINEAGE POWER
16
Advanced Data Sheet February 10, 2011
QBDW033A0B Series Power Modules; DC-DC Converters 36-75Vdc Input; 9.6-12Vdc Output; 33A Output Current
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Product codes QBDW033A0B41Z QBDW033A0B41-HZ QBDW033A0B41-PHZ Input Voltage 48V (3675Vdc) 48V (3675Vdc) 48V (3675Vdc) Output Voltage 12V 12V 12V Output Current 33A 33A 33A Efficiency 96% 96% 96% Connector Type Through hole Through hole Through hole Comcodes TBD TBD TBD
Table 2. Device Options
Characteristic
Form Factor Family Designator Input Voltage Output Current Output Voltage* Pin Length Action following Protective Shutdown* On/Off Logic* Q BD W 033A0 B 8 6 5 4 1 P
Character and Position
Definition
Q = Quarter Brick BD=BARRACUDA Series W = Wide Range, 36V-75V 033A0 = 033.0 Amps Maximum Output Current B =12.0V nominal Omit = Default Pin Length shown in Mechanical Outline Figures 8 = Pin Length: 2.79 mm 0.25mm , (0.110 in. 0.010 in.) 6 = Pin Length: 3.68 mm 0.25mm , (0.145 in. 0.010 in.) 5 = Pin Length: 6.35 mm 0.25mm , (0.250 in. 0.010 in.) Omit = Latching Mode 4 = Auto-restart following shutdown (Overcurrent/Overvoltage) Omit = Positive Logic 1 = Negative Logic
Options
Ratings
Mechanical Features Customer Specific RoHS
Omit = Standard open Frame Module P = Active load sharing (Parallel Operation) H H = Heat plate, for use with heat sinks or cold-walls XY XY = Customer Specific Modified Code, Omit for Standard Code Omit = RoHS 5/6, Lead Based Solder Used Z Z = RoHS 6/6 Compliant, Lead free
* Feature may be reconfigured from factory default using PMBus. See Feature Descriptions for additional details.
Asia-Pacific Headquarters Tel: +65 6593 7211 Europe, Middle-East and Africa Headquarters Tel: +49 89 878067-280 India Headquarters Tel: +91 80 28411633
World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com
Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved.
Document No: ADS10-006 ver 0.3 PDF Name: QBDW033A0B_ADS.pdf


▲Up To Search▲   

 
Price & Availability of QBDW033A0B41-PHZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X